ELECTRIC MOTOR DRIVEN PUMP
Our HP-40 Transfill System is be supplied with an electric motor driven pump which is whisper quite. It can pump 1650 SCFH or up to 66 “E” cylinder per hour. Higher capacities up to 14,000 SCFH are available. A vertical piston is used with trouble free room temperature seals. Slow speeds (60 cycles/min.) ensure long life.

SIMPLE INSTALLATION
All components of the system (except analyzer) are mounted on a 5 ft x 3 ft. Stainless Steel Skid. Simply pipe system vents outdoors and connect electric power to the system.

POWER REQUIREMENTS
For lower operation costs, 3-Phase motors are recommended. 2 HP 230 VAC 3-Phase 60 Hz can be used at pressures up to 3,000 PSI. required to fill fiber wrapped cylinders. 2 HP 220 VAC 1-Phase 60 Hz can be used at pressures up to 2,500 PSI required to fill aluminum and steel cylinders.             

SAFE
Five (5) independent safety devices assure safe, reliable operation. They include: Automatic Shutoff Timer, (3) Pressure Relief Valves, Rupture Discs and (3) Speed Controls.

COST SAVINGS
If you use (100) “E” cylinders per week, you can save about $2,000.00 per month. For a detailed cost analysis call, send us an E-mail or download our Cost Analysis Worksheet.

UTILIZE EXISTING EQUIPMENT
Existing components of a gas to gas Transfill system including manifolds, regulators, vacuum pump and Oxygen analyzer can in most cases be integrated into our HP-40 Transfill System.

EFFICIENT USE LESS OXYGEN
Our Patented (#5,819,544) system uses a pump emersed in 140 liters of liquid Oxygen in a vacuum insulated container. The pump would only require cool down for the first batch of cylinders filled and would not require additional cool downs.

Competitive systems continually flow liquid Oxygen into the pump. The competitive systems require cool down for each batch of cylinders filled with typical liquid Oxygen loss of 100 to 200 liters for 8 hours of operation.

EQUIPMENT RENTAL
If you have an existing gas to gas transfill system, the basic Liquid Oxygen Pump can be supplied on a rental basis. Please call or send an E-mail for more information.

OTHER GASES
The HP-40 can be used to transfill Nitrogen or Argon as well as Oxygen. The HP-40 is also ideal for providing high pressure Nitrogen gas for pressure testing, Lasers, Autoclaves, Injection Molding etc.

CONVENIENT - TIME SAVING
Automatic operation, Simply load cylinders, vent, evacuate and start the pump. The alarm will sound when the cylinders are ready to be checked and close to being full. Two separate fill manifolds allow the operator to fill one manifold while loading and then evacuating the other. Can fill cylinders with two different operating pressures up to 3,000 PSI at the same time. Can gas to gas transfill up to three ‘E’ cylinders at a safe controlled speed without using the pump.

D.O.T., C.G.A. AND F.D.A. APPROVALS
We have over 40 years experience in the manufacture of Cryogenic Equipment and we are D.O.T., C.G.A. and F.D.A. approved.

Our HP-40 Transfill Equipment and Components meet all applicable specifications.